Siemens SINUMERIK 808D Nodes

Read named points from the PLC of a SINUMERIK 808D, write setpoints, and send commands the PLC program acts on, from a pipeline.

Status
Beta
Operations
Read Points · Write Point · Send Command
Areas
DB · M · I · Q · SM · C · T
Limits
A command is sent at most once

Read and write the integrated PLC of a Siemens SINUMERIK 808D from pipelines, by address. Each operation has its own node in the Pipeline Designer: Siemens SINUMERIK 808D Read Points, Siemens SINUMERIK 808D Write Point and Siemens SINUMERIK 808D Send Command.

For connection setup, the address grammar and per-function fields, see the Siemens SINUMERIK 808D connection guide.

Configuration Quick Reference​

FieldWhat you chooseDetails
ParametersConnection, Function, Function Parameters, Timeout OverrideSelect the SINUMERIK 808D connection profile, pick a function, bind parameters with expression support, and optionally override the timeout.
SettingsDescription, Timeout (seconds), Retry on Timeout, Retry on Fail, On ErrorNode description, maximum execution time, retry behaviour on timeout or failure, and error strategy. All execution settings default to pipeline-level values.

Each node also delivers the call's own facts under _metadata, beside the four every connected node carries: _metadata.method (the operation that ran, e.g. sinumerik808d.read), _metadata.connectionId (the connection it ran over) and _metadata.protocol (sinumerik808d).


SINUMERIK 808D Read Points nodeSINUMERIK 808D Read Points node

Read Points node

Read Points Node​

Read many named points, each by its 808D address, in the fewest requests. Runs a sinumerik808d.read function.

Node Configuration​

ParameterTypeRequiredDescription
ConnectionSelectionYesSINUMERIK 808D connection profile to use
FunctionSelectionYesA sinumerik808d.read function from the selected connection
Function ParametersDynamicVariesNone: the points are part of the function, set on the function form, not bound in the node. See Read Points.
Timeout OverrideNumber (seconds)NoOverride the default function timeout

Output Structure​

{
"result": {
"count": 2,
"values": { "spindleRunning": true, "partCount": 1520 },
"quality": "good",
"totalDataPoints": 2,
"totalReads": 2
},
"_metadata": { "success": true, "method": "sinumerik808d.read", "protocol": "sinumerik808d", "connectionId": "<connection-id>", "functionId": "<function-id>", "durationMs": 6, "timestamp": "2026-11-21T08:30:00Z" }
}
FieldTypeDescription
result.valuesobjectEvery point by its name, typed by its data type: a boolean for a BIT and a /STATUS, a number for the integers, the counters, the timers and REAL
result.countnumberHow many points were decoded
result.qualitystringgood: a refusal from the 808D fails the node instead of storing a value
result.totalDataPointsnumberHow many points were requested
result.totalReadsnumberHow many requests were sent to the 808D
{{ $node["Siemens SINUMERIK 808D Read Points"].result.values.partCount }}
How points are grouped

Points of one area (and one data block) that lie within 32 bytes of each other share a request. A shared request is never longer than one S7 request carries at the PDU the 808D answered (222 bytes at a PDU of 240), so each group goes out as exactly one request and a multi-byte value is never read half in one request and half in the next. A bit is read with its byte. Each counter and each timer takes a request of its own. totalReads is the number of requests the node sent.


SINUMERIK 808D Write Point nodeSINUMERIK 808D Write Point node

Write Point node

Write Point Node​

Write one setpoint: a data block, flag (M) or output (Q) address, or a system flag byte or word from SMB30 (SM). Runs a sinumerik808d.write function.

A bit is written as a bit, so the PLC's other bits of that byte are not touched. Inputs, system flag bits, counters and timers are not written. Writing the same value twice leaves the address as it was, so when the 808D does not answer in time, Retry on Fail may send the write again. The node does not run in a pipeline started by a late (replayed) input.

Node Configuration​

ParameterTypeRequiredDescription
ConnectionSelectionYesSINUMERIK 808D connection profile to use
FunctionSelectionYesA sinumerik808d.write function from the selected connection
Function ParametersDynamicVariesaddress and value, both of which support ((paramName)) templates. See Write Point.
Timeout OverrideNumber (seconds)NoOverride the default function timeout

Output Structure​

{
"result": {
"address": "DB1000/40",
"dataType": "INT",
"value": 80
},
"_metadata": { "success": true, "method": "sinumerik808d.write", "protocol": "sinumerik808d", "connectionId": "<connection-id>", "functionId": "<function-id>", "durationMs": 5, "timestamp": "2026-11-21T08:30:00Z" }
}
FieldTypeDescription
result.addressstringThe 808D address written
result.dataTypestringThe type the value was written as
result.valueanyThe value written, as the address holds it

SINUMERIK 808D Send Command nodeSINUMERIK 808D Send Command node

Send Command node

Send Command Node​

Send one value the PLC program acts on and then clears, such as a request bit or a job number. Runs a sinumerik808d.command function. Its addresses and output are those of the Write Point node.

A command is sent at most once. When the 808D does not answer in time, the node fails with COMMAND_OUTCOME_UNKNOWN and is never sent again automatically: the PLC program may already have acted on it. Retry on Fail does not apply to it.

Node Configuration​

ParameterTypeRequiredDescription
ConnectionSelectionYesSINUMERIK 808D connection profile to use
FunctionSelectionYesA sinumerik808d.command function from the selected connection
Function ParametersDynamicVariesaddress and value, both of which support ((paramName)) templates. See Send Command.
Timeout OverrideNumber (seconds)NoOverride the default function timeout

Output Structure​

{
"result": {
"address": "M20.0",
"dataType": "BIT",
"value": true
},
"_metadata": { "success": true, "method": "sinumerik808d.command", "protocol": "sinumerik808d", "connectionId": "<connection-id>", "functionId": "<function-id>", "durationMs": 5, "timestamp": "2026-11-21T08:30:00Z" }
}
FieldTypeDescription
result.addressstringThe 808D address written
result.dataTypestringThe type the value was written as
result.valueanyThe value sent, as the address holds it

A value the address cannot hold, an input, a system flag bit or one of SMB0-SMB29, a counter or a timer fails the node before anything is sent to the 808D.

Safety first

Validate values in a Condition node before writing to a machine. A flag or a data block value can start a spindle or a program through the PLC program immediately.


Settings Tab​

All three node types share the same Settings tab:

SettingTypeDefaultDescription
DescriptionText-Optional description displayed on the node
Timeout (seconds)NumberPipeline defaultMaximum time the node may run before timing out
Retry on TimeoutTogglePipeline defaultAutomatically retry the node if it times out
Retry on FailTogglePipeline defaultAutomatically retry the node if it fails (never a command whose outcome is unknown)
On ErrorSelectionPipeline defaultError strategy: Pipeline Default (the pipeline's Error Handling setting), Stop Pipeline or Continue Execution

When left at their defaults, these settings inherit from the pipeline-level execution configuration.