Allen-Bradley PCCC Nodes
Read and write integers, bits, floats, longs, strings, timers, counters and status words on SLC 500, MicroLogix and PLC-5 controllers from a pipeline.
- Operations
- Read Address · Read Block · Write Address
- Limits
- 188 bytes per request: 94 words, 47 floats or longs
- Writes
- Bits by masked write; never buffered
Use Allen-Bradley SLC 500, MicroLogix and PLC-5 controllers in pipelines. Each function authored on an Allen-Bradley PCCC connection is available as a matching node in the Pipeline Designer: Allen-Bradley PCCC Read Address, Allen-Bradley PCCC Read Block and Allen-Bradley PCCC Write Address.
For connection setup (EtherNet/IP and the DF1 serial line), the address forms and what each one returns, see the Allen-Bradley PCCC connection guide.
These controllers do not send data on their own, so there is no trigger node: to poll one, drive the reads from a Schedule trigger.
Configuration Quick Reference
| Field | What you choose | Details |
|---|---|---|
| Parameters | Connection, Function, Function Parameters, Timeout Override | Select the Allen-Bradley PCCC connection, pick a function, bind parameters with expression support, and optionally override the timeout. |
| Settings | Description, Timeout (seconds), Retry on Timeout, Retry on Fail, On Error | Node description, maximum execution time, retry behaviour and error strategy. All execution settings default to pipeline-level values. |
Every node shares the same Parameters: Connection (the Allen-Bradley PCCC connection profile), Function (a function of the node's type on that connection), Function Parameters (auto-populated from the function schema, with expression syntax {{ expression }} for dynamic values) and an optional Timeout Override in seconds. Each node receives the output of the previous node as input, which function parameter expressions can reference as $input.
The call's own facts ride along under _metadata next to the four every connected node carries. Every Allen-Bradley PCCC node delivers _metadata.method (the operation that ran, e.g. pccc.read), _metadata.connectionId (the connection it ran over) and _metadata.protocol (pccc).


Read Address node
Allen-Bradley PCCC Read Address Node
Supported Function Types:
| Node | Function | Purpose | Common Use Cases |
|---|---|---|---|
Allen-Bradley PCCC Read Address (connected.pccc.read) | pccc.read | Read one value, or a run of consecutive values, from a data-file address | A production count on a schedule, a timer's accumulated value, an alarm bit |
The node reads the address the function names, or Count consecutive values. The file letter of the address fixes the data type. See Read Address for the parameters and Addresses for what each address returns.
Output Structure
{
"result": {
"address": "N7:0",
"fileType": "integer",
"value": 1234,
"quality": "good"
}
}
With Count more than 1, value is a list. A whole timer, counter or control element is one object with its two words and its status bits:
{
"result": {
"address": "T4:0",
"fileType": "timer",
"value": { "PRE": 100, "ACC": 5, "EN": true, "TT": true, "DN": false },
"quality": "good"
}
}
| Key | Meaning |
|---|---|
result.address | The address read, in one standard form: b3/21 comes back as B3:1/5, S:1/5 as S2:1/5 |
result.fileType | The kind of data file: status, bit, timer, counter, control, integer, float, string, ascii or long |
result.value | The value: a number, true/false for a bit, text for a string or ASCII element, or an object for a whole timer (PRE, ACC, EN, TT, DN), counter (PRE, ACC, CU, CD, DN, OV, UN, UA) or control element (LEN, POS, EN, EU, DN, EM, ER, UL, IN, FD). A list of values when Count is more than 1 |
result.quality | good. A refusal by the controller fails the node instead of storing a value, so a value that reached the result is the controller's own reading |
Read a value with $node["Read Count"].result.value, and a part of a whole timer with $node["Read Timer"].result.value.ACC.


Read Block node
Allen-Bradley PCCC Read Block Node
Supported Function Types:
| Node | Function | Purpose | Common Use Cases |
|---|---|---|---|
Allen-Bradley PCCC Read Block (connected.pccc.read.block) | pccc.read.block | Read many named addresses in the fewest requests | A machine's counts, setpoints and alarm bits in one node |
The node reads every point of the function and returns each value by its name. Points in the same data file are read in one request, with the elements between them, when they fit. A point the controller refuses is reported by name without failing the others; the node fails only when the link fails. See Read Block for the parameters.
Output Structure
When every point was read:
{
"result": {
"count": 3,
"values": { "Count": 1234, "Scrap": 3, "Alarm": true },
"quality": "good",
"totalDataPoints": 3,
"totalReads": 2
}
}
Here Count (N7:0) and Scrap (N7:1) share one request and Alarm (B3:0/5) takes a second.
When a point was not read, it is missing from values, its reason is in errors under its name, and quality is bad:
{
"result": {
"count": 2,
"values": { "Count": 1234, "Alarm": true },
"errors": {
"Spare": "pccc: the PLC refused the request: the address does not point to something usable: the file or the element does not exist in the PLC, or the file is of another type than the address says (status 0xF0, extended status 0x06)"
},
"quality": "bad",
"totalDataPoints": 3,
"totalReads": 3
}
}
| Key | Meaning |
|---|---|
result.values | Every point that was read, by its name |
result.errors | The reason for each point that was not read, by its name. Present only when a point was not read |
result.count | How many points were read |
result.totalDataPoints | How many points were requested |
result.totalReads | How many requests the points were merged into, including the requests that asked again point by point after a refusal |
result.quality | good when every point was read, bad when one was not |
Read a point with $node["Line Status"].result.values.Alarm. Check $node["Line Status"].result.errors before relying on every point being present.


Write Address node
Allen-Bradley PCCC Write Address Node
Supported Function Types:
| Node | Function | Purpose | Common Use Cases |
|---|---|---|---|
Allen-Bradley PCCC Write Address (connected.pccc.write) | pccc.write | Write one value, or a run of consecutive values, to a data-file address | Setpoints, recipes, a timer's preset, alarm acknowledgement bits |
The node writes the function's value, or a list of values to consecutive elements in one request. A single bit is changed by the controller itself with a masked write, so bits the program changes in the same word are never overwritten. The status bits of timers, counters and control, and a bit of a long, cannot be written. See Write Address for the parameters and the write rules.
A write is never buffered for later delivery, and it is refused in a run started by a late (replayed) input unless the node allows late input. A value that does not fit its address fails the node before anything is sent to the controller.
Output Structure
{
"result": {
"address": "N7:10",
"fileType": "integer",
"value": "72"
}
}
| Key | Meaning |
|---|---|
result.address | The address written, in one standard form: b3:0/5 comes back as B3:0/5, T4:0.pre as T4:0.PRE |
result.fileType | The kind of data file: status, bit, timer, counter, control, integer, float, string, ascii or long |
result.value | The value as given, after parameter substitution: "72", or the list "[120, 45, 3]" |
Always validate values in a Condition node before writing to a controller. A setpoint or a bit can move a motor, valve or actuator immediately.
Errors
| Error | Meaning | Retried by the node settings? |
|---|---|---|
the PLC refused the request: … naming the address or the command (the file or element does not exist, the file is of another type, the file is shorter than the request needs, illegal command or format) | The controller refused the request, with its own reason and status codes | No: the result is permanent |
the PLC refused the request: the processor is in Program mode | The controller is in Program mode | Yes |
| A refusal before anything is sent (an address that is no address, a long on an SLC 500 or PLC-5, a value that does not fit, a status bit, a list too long for one request) | MaestroHub refused the request; nothing reached the controller | No |
… (CIP status 0x08). A ControlLogix or CompactLogix is reached with the EtherNet/IP connector instead | The device answers EtherNet/IP but is no PCCC processor | No |
no answer from the device / no answer from the PLC on the serial line | The request was sent and not answered in time | Yes. A write sent again leaves the controller in the same state as one write of the same value |
not connected | The connection is down | Yes |
The full list of messages, with what to change for each, is in the guide's Troubleshooting.
Settings Tab
All Allen-Bradley PCCC node types share the same Settings tab:
| Setting | Type | Default | Description |
|---|---|---|---|
| Description | Text | - | Optional description displayed on the node |
| Timeout (seconds) | Number | Pipeline default | Maximum time the node may run before timing out |
| Retry on Timeout | Toggle | Pipeline default | Automatically retry the node if it times out |
| Retry on Fail | Toggle | Pipeline default | Automatically retry the node if it fails |
| On Error | Selection | Pipeline default | Error strategy: Pipeline Default (the pipeline's Error Handling setting), Stop Pipeline or Continue Execution |
When left at their defaults, these settings inherit from the pipeline-level execution configuration. The retry settings do not retry a request the controller refused for its address or its command (see Errors).
Use the Test button in the function form (on the connection page) to run every Allen-Bradley PCCC function against the live controller before wiring it into a pipeline. It is the fastest way to catch a wrong PLC family, an address the program does not have, or a file letter that does not match the file.